WF beam torsion - Structural engineering general discussion - Eng …
Nov 3, 2024 · I’m using a W21x44 in the first one and framing the exterior wood trusses into the side. For the 2nd detail, I’m using a W12x26 with a WT12x31 because the beam extends past the step so the beam needs to be lower, but the WT is needed for a portion of the span just to pick up the interior wood trusses on the right side of the detail.
50ksi W21x44 over 60' long Welding 2 together? 4 - Eng-Tips
Jun 28, 2006 · 50ksi W21x44 over 60' long Welding 2 together? 4. Thread starter crozroz0000; Start date Sep 7, 2006; Status
Historical shapes - Structural engineering general discussion - Eng …
Mar 2, 2010 · W21x44 is a very light shape. Upvote 0 Downvote. Mar 2, 2010 #6 paddingtongreen Structural. Sep 28, 2009 ...
Beam-Column Design - Structural engineering general discussion
Jul 25, 2001 · I have a beam that is supporting two bar joists. There is NO kicker from the bar joist bracing the bottom flange against twist, however, it appears that they considered the bar joist as bracing in the weak direction. Is this standard? The axial load on the original design drawing is 147k. The beam used is a W21x44. Its span is 20'. Fy=36ksi.
Steel Beam Bearing on CMU Repair - Eng-Tips
Nov 5, 2012 · I'm working on an addition to an existing building and during demo, the contractor discovered the situation shown in Photo #1. It's an existing W21x44 bearing at the end of a CMU wall and the CMU under the beam bearing has cracking. There's a 1/2" steel bearing plate below the beam with...
W21x44 Dimensions and Structural Engineering Q&A - JustAnswer
For your approximate 40' span and 17' tributary width that supports your ceiling and a flat roof, you can use a W21x44 (50 ksi) steel beam. This beam is 6.5" wide, 20.625"deep and weighs 44 pounds per foot of beam. You will need to provide a timber nailer (2x8) bolted to the top flange of the steel beam.
Simply Supported Beam Design - Structural engineering ... - Eng …
Feb 2, 2004 · I am reviewing a design that has a beam subjected to 200k-ft max moment and a 32 ft span, the designer has specified a W21x44. When I checked the beam via ASD the compressive flange would have to be braced at least every 4.7-ft to meet the flange criteria. I think the designer is just...
US shapes versus British Shapes - Structural engineering ... - Eng …
Apr 8, 2006 · I have not found the British Sections limiting in their options - unless I am missing something the difference in wt between W21x44(at 65.4 kg/m) and UB533x165x66 kg/m and W24x55 ( 81.8 KG/m) and UB 610x178x82 kg/m is insignificant.
Dining Area Vibration Values - Structural engineering general ...
Jun 27, 2005 · I go from W21x44 girders with W16x26 nrsmd to W24x55/W21x44's. Upvote 0 Downvote. Mar 10, 2011 #3 rob768
Steel Composite Beam and Deck Cold Joint - Eng-Tips
Mar 9, 2006 · Currently beam is W18x35 and needs to be a W21x44 if it were to be non composite. Upvote 0 Downvote. Oct ...