A W10X17 steel I beam 40 foot long can support how much weight…
2014年2月14日 · JACUSTOMER-vbhrzmzz- : I am wanting to use them at the 40 foot length to use for a parts storage in a farm shop building with the area being about 5 foot wide with shelves along the wall and just a walk area in front of them and maybe supports one or two places under the area where the weight is. and the front walk area with NO supports.
Load Capacity of a W10x17 I-Beam: 21ft to Inches Conversion
Customer: How much weight can an I beam support its w10x17 21 ft long Contractor's Assistant: Tell me a bit more about what's going on so we can help you best. Customer: we’ll I need to find out the load capacity of this I beam that is 21 ft long It’s depth is 10in and it’s 4” wide Contractor's Assistant: Is there anything else the ...
Related Customer Questions - JustAnswer
W10x15 won't work. Even though the beam is deeper, the flange is narrow, which makes it susceptible to lateral torsional buckling. There is no W10x18, but a W10x17 works. It's close enough to worry me a little, though. If you want to use a W10, I would use a W10x22 - it has a 5-3/4" flange width.
DECK LOAD CALCULATOR for HOT TUB EXPERT Q&A - JustAnswer
2. The existing 21' clear span steel beam is a W10x17 (based on the dimensions you provided) 3. 7'x7' hot tub placed on deck. Assumed 100 psf loading over 49 sq ft hot tub footprint. Based on theses assumptions: A. 2x12 Douglas Fir (#2 grade) deck joists spaced at 12" o.c. and spanning 12' are at 90% of the allowable Bending Stress value. B.
Span 32' of 16" o.c. 2X10's floor joist, no load bearing ... - JustAnswer
The W10x17 will only work if you can brace the top flange against lateral movement. Read less. 0 Likes ...
I have a span of 30 feet I have to support. The beam ... - JustAnswer
You can use a W10x17 (50 ksi) steel beam (4" wide, 10.125" deep and 17 plf) ...
I am working on a school project and I'd like to double
W10x17 (50 ksi) steel beams. For the 25' clear span main roof beams, spaced at 25' o.c. you can use the following: W18x35 (50 ksi) steel beams. All of these beams will need to be adequately laterally braced.
1 have an 18 foot span and want to use a 2 ton roller hoist in the ...
W10x17 or. W8x18. This includes a factor of safety per IBC2018 for an impact loading of 2.0x the load capacity. The type of steel and grade is specified by the AISC steel manual for standard shapes. If you buy any W-beams, they all must adhere to the AISC requirements (50ksi) ~JAYCE GREFRATH, P.E.
I have a 30ft span holding up a light roof and need to ... - JustAnswer
Customer: I have a 30ft span holding up a light roof and need to know what size I-Beam I need to use. I really just need to know how much weight a 4" wide x 10" tall x 30ft long I-Beam can hold in the middle (15ft).
I need to build a bridge across a brook on my farm. I have a farm ...
6. You do not need to ask another question. You will have the opportunity to leave a Bonus if you so desire. For the 5,000 lb maximum load truck, you could use four W10x17 (50 ksi) steel beams. The beam is 4" wide, 10.125" deep and weighs 17 pounds per foot of beam. I would just stick with the W10x22 steel beams, you will not get a significant ...