RT Image Module – DICOM Standard Browser - Innolitics
This module specifies the Attributes of the RT Image Module, which describe RT-specific characteristics of a projection image. The image described by these Attributes must be a radiotherapy image acquired or calculated using a conical imaging geometry.
Enhanced RT Image CIOD – DICOM Standard Browser - Innolitics
The Enhanced RT Image IOD represents projection images generated before, during or after Radiotherapy treatment sessions. The projection images may be acquired directly or may be derived ("reconstructed") from volumetric data such as CT.
RT Image CIOD – DICOM Standard Browser - Innolitics
The focus for this Radiotherapy Image IOD (RT Image IOD) is to address the requirements for image transfer found in general radiotherapy applications performed on conventional simulators, virtual simulators, and portal imaging devices.
RT Image SID Attribute – DICOM Standard Browser - Innolitics
(3002,0026) RT Image SID: 3: Decimal String (3002,0032) Meterset Exposure: 3: Decimal String (300A,00CC) Imaging Device-Specific Acquisition Parameters: 3: Long String (300C,0007) Referenced Reference Image Number: 3: Integer String (300C,0008) Start Cumulative Meterset Weight: 3: Decimal String
Image Plane Pixel Spacing Attribute – DICOM Standard Browser
The Image Plane Pixel Spacing (3002,0011) Attribute shall always be defined on the image plane, i.e., at the radiation machine source to image plane distance specified by RT Image SID (3002,0026).
Patient Position Attribute – DICOM Standard Browser - Innolitics
2012年8月8日 · Images with modality SC or VL serve as visible light photos for visual setup control. Images with modality RTIMAGE serve as reference images on plan level. RT Images present in this Sequence shall not be referenced in the Referenced Reference Image Sequence (300C,0042) of the RT Beams Module.
Image Type Attribute – DICOM Standard Browser - Innolitics
If the pixel data of the derived Image is different from the pixel data of the source images and this difference is expected to affect professional interpretation of the image, the Derived Image shall have a UID different than all the source images.
RT Plan CIOD – DICOM Standard Browser - Innolitics
The focus for this Radiotherapy Plan IOD (RT Plan IOD) is to address the requirements for transfer of treatment plans generated by manual entry, a virtual simulation system, or a treatment planning system before or during a course of treatment.
Enhanced RT Image Module – DICOM Standard Browser - Innolitics
Enhanced RT Image: M: Module - Image (0008,0008) Image Type: 1: Code String (0018,8150) Exposure Time in µS: 2: Decimal String (0054,0410) Patient Orientation Code Sequence: 1: Sequence (3002,0106) Start Cumulative Meterset: 2C: Double (3002,0107) Stop Cumulative Meterset: 2C: Double (300A,063F) Treatment Position Sequence: 1C:
X-Ray Image Receptor Angle Attribute – DICOM Standard Browser
2014年8月8日 · The X-Ray Image Receptor Angle (3002,000E) specifies the rotation of the image receptor device in the IEC X-RAY IMAGE RECEPTOR PLANE. A positive angle corresponds to a counter-clockwise rotation of the X-Ray Image Receptor as viewed from the radiation source in the IEC GANTRY coordinate system.