R502, is it worth selling? - HVAC-Talk
2010年9月25日 · R502 ls still used. On old equipment with a small charge slightly short of refrigerant why would anyone think of converting. The cost of conversion done properly and drop in efficiency just don't make sense. Beyond ozone depletion.R12 and R502 were probably the greatest advancements in 20th century refrigeration.
r502 low temp replacement - HVAC-Talk
2007年2月23日 · I thought HP80 run at lower discharged temperature than R502. In fact it runs at 5 degrees lower. It also gives 10% more capacity. Even though its discharge pressure is higher than R502. In fact 40 PSIG higher. Even though its suction pressure is higher than R502. In fact 5 PSIG higher So higher pressure does not mean bad at all.
mineral oil in R502 system - HVAC-Talk
2010年3月9日 · Can mineral oil be used under any circumstances with R502? I recently checked a system where the compressor was definately low on oil with very little showing in the crankcase sight glass. This was a Copeland comp #EAVB-021ECAV. I beleive Copeland states that the oil level in the compressor should be at the 3/4 mark of the sight glass.
Replacing R502, low temp applications - HVAC-Talk
2004年12月1日 · I am requesting info on what y'all did for replacing R502 in low temp applications. Please list the refrigerant blend you switched over to, the oil you used and and issues you discovered in the process. Thank you [/QUOTE Hi 404 is my best working methood
Retrofiting a R-502 system to R-404a - HVAC-Talk
2010年8月28日 · The cap tube sizing is the same for R502 and R404A. Supco Capillary Tube Selection. Last edited by ...
Replacement refrigerant for R502 - HVAC-Talk
2013年11月12日 · Join Date Oct 2003 Location Minnesota Posts 172 Post Likes Likes (Given) 0 Likes (Received) 0 Dislikes (Given) 0 Dislikes (Received)
R502 - HVAC-Talk
2015年12月20日 · Found an almost full 30lb jub of R502 in a building (former hospital) that my employer recently inherited. Was tucked behind a walk-in refer in the basement that appears to have been changed out to r404A years ago.
R502 with POE oil - HVAC-Talk
2013年8月26日 · The system supposed to cool the chamber to -30C and has been doing it Ok. With the fades out of R502 , Danfoss changed the compressor with another name and filled with POE oil . This new compressor supposed to work with R404a. When the system is with this new compressor with POE oil and about 80%(from R502 amount)
R-502 almost 30lb tank - HVAC-Talk
2023年1月29日 · Hey folks, I got a tank of R-502. It has about 31 lbs of R-502. I am not sure what's it worth, but it seems like it's a lot.
R22 to R502 machine for leak detection - HVAC-Talk
R22 to R502 machine for leak detection Would it be ok to pressurize a R502 taylor soft serve machine using r22 or r404a to find a leak? I have a freon/halogen leak detector but it doesn't detect r502, but does detect 404a and r22.