
What's the difference between 'lead', 'cable' and 'wire'?
2016年9月27日 · Cable - multiple wires or strands bound together for better mechanical / electrical properties than a single wire of similar thickness. Line or Lead (elect.) - a wire or …
Lead shielded cable. | Contractor Talk - Professional Construction …
2008年3月24日 · There's quite a bit of lead jacketed cable in my area. Forerunner to UF cable. I normally find it run to detached garages, post lights, fountains, and other places where we'd …
Paint shaver pro | Contractor Talk - Professional Construction and ...
2005年7月25日 · Lead paint One of the reasons we went the Paint Shaver route was the lead paint issues. The Paint Shaver, ran through a Dust Deputy cyclone and a HEPA filter solves …
Question about meggers | Contractor Talk - Professional …
2008年5月28日 · After looking at a diagram in some literature called "A stitch of time" I noticed (for say a power cable) they tied one side of the cable to ground and attached a lead from the …
In floor heat | Contractor Talk - Professional Construction and ...
2016年1月18日 · In the event that the registration card and or heating cable tests log is not completed and returned then the resolution for failure of the Products to meet this warranty …
Generator wont produce electricity? Why? | Contractor Talk ...
2009年3月1日 · Sorta. You can plug a corded drill in, chuck up a drill bit in it, chuck up a cordless drill on the other end of that bit, and use the cordless to spin the corded drill while holding in …
Ditra Heat stopped working | Contractor Talk - Professional ...
2019年5月22日 · You'll find the cold lead with the tag on it is way to long, cut the cold lead the code required 6" service length out of the box, wrap the tag around the cable. That's what it is …
Lead lined drywall | Page 2 | Contractor Talk - Professional ...
2009年3月11日 · It only gets released when it's destroyed. If you burnt fuel it's released, cut paint with a circuler saw its released, cut lead lined drywall with a circuler saw its released. Same …
Thickness of lead flashing | Contractor Talk - Professional ...
2010年7月28日 · So far all I have found here is lead flashing that is 1mm thick. Which is 2.5 lbs per sq. foot. BTW I found I can get lead that is much thicker even bricks and bars of lead. But …
55 volts on both hot and neutral, what the heck!? - Contractor Talk
2006年2月17日 · Type AC cable (aka - BX) uses the cable armor for the ground path. This isn't always the best ground, and does't get better with time. Recheck your readings by connecting …