Agilent E4406A Vector Signal Analyser - Page 1 - EEVblog
2015年4月5日 · I tried this (via an anti alias LPF) in the E4406A and the E4406A limited out at -136dBc/Hz at maybe 3-10kHz offsets. Not bad! The idea would be to use an external LO and mixer to make a fairly decent phase noise measuring capability if a coax relay was fitted here. Note: My E4406A has the 14bit IF module which will help here.
Agilent E4406A Value - Page 1 - EEVblog
2016年9月20日 · The E4406A VSA *is* a Spectrum Analyzer (VSA = Vector Spectrum Analyzer, i.e. it uses FFT for spectrum analysis), however since it was designed for testing cell phone transmitters it comes with various limitations, like a max span of 10Mhz (or 100Mhz with the HSDPA software option).
Agilent E4406A Vector Signal Analyser - Page 3 - EEVblog
2015年10月14日 · My system is WIN XP 32bit SP2, E4406A Hardware is FW A.10.08 If I use SCPI commands via telnet it works fine. Both TELNET and Socket ports are ON. I've tried fresh windows installation with 89600 V9.02, V11.21, V12.02 I'm sure that I'm missing something, any help will be greatly appreciated.
Agilent E4406A Vector Signal Analyser - Page 4 - EEVblog
2015年10月20日 · Hello My E4406A has a low frequency drop off at about 200Khz--some have wondered about if the front end 7dB attenuator also have a dc block inbuilt! I have replaced this attenuator with a pecision narda--and the answer is simple-yes the original made by weinschel have a dc bloc,so now my E4406A goes down to a few Hz.Now using an external dc ...
Agilent E4406A Vector Signal Analyser - Page 5 - EEVblog
2020年9月15日 · This is a bit of a necropost, but this is *the* thread that comes up when searching Google on the topic of E4406A and the 89600 VSA software. I just got this working so I thought I would share what was involved. This will allow one to use unsupported VSA software with their unsupported Agilent E4406A.
E4406A died PSU - Page 1 - EEVblog
2016年11月11日 · For posterity, he was referring to these: My E4406A would generally boot up about 5-10 minutes after turning on the power, but lately it was taking more like 30 minutes to 1 hour so it was time to deal with it. The 47 uF cap showed higher-than-normal ESR when cold, but was close to normal when warm. The 33 uF cap was almost completely open.
E4406A VSA key documentation? - Keysight
2008年12月8日 · The E4406A requires that you manually set an IP address. Using the 89601A software will allow you to demodulate many digital formats. Likewise, you can use the E4406A to capture I/Q data and use MATLAB to demodulate it. The E4406A has 1 mega sample capture memory and 8 MHz bandwidth.
Agilent E4406A Vector Signal Analyser - EEVblog
Agilent E4406A Vector Signal Analyser << < (20/22) > >> Andrey_UR: Hello colleagues! Whether there is an opportunity to prolong the term of work of the 89600 program? I have installed the program a year ago and didn't use it, and now I want to resume work. How do you solve this problem at full-time employment with the E4406A? Thanks a lot Andrey
E4406A Phase Noise in wide span - Page 1 - EEVblog
2023年9月27日 · Hey guys, i've recently acquired an E4406A transmitter tester. Unfortunately it shows some unexpected behaviour: When i feed it a Signal at 800MHz (frequency doesnt seem to matter though) and 0dBm with the span set to 1MHz and the RBW to 20kHz (AUTO) a noise marker at +500kHz (left of the screen) indicates -120dBm/Hz.
HP E4406A Questions - Page 1 - EEVblog
2019年9月22日 · Thank you guys for sharing the information about the E4406A. I recently acquired one from Ebay. It is a very nice VSA but the flash memory on my E4406A is limited. I bought a used E4406-60060 CPU board that came with a flash memory card installed with it. I want to upgrade the flash memory card for it but it did not come with a utilities disk.