
directional drilling | Information by Electrical Professionals for ...
2015年2月24日 · There are HDPE assemblies out there with conductors already installed in them - this can be labor saving, especially for directional boring applications, but they work great for instances where you are plowing the line in instead of trenching as well.
Directional Boring Warning Ribbon | Information by Electrical ...
2021年2月15日 · We are pricing to move an overhead service to underground, I inform AHJ, local inspector for the area that we are considering directional boring due to the circumstances. He asks how we plan on putting the metallic direct burial tape or some type of warning tape 12" above the bore for future indication.
Directional Boring for electrical conduits. | Information by Electrical ...
2015年11月4日 · I have a project that will use directional boring to install some conduits on the secondary side of a utility transformer. Basically the electrical conduits routed from the utility transformer, under a concrete courtyard, to the building main electrical room. I am not too familiar with this directional boring technique.
Boring Under 6' Sidewalk With Pressure Washer.
2014年3月23日 · Welcome Spring To All. Hello, I have to bore a hole under a 6' sidewalk. I am thinking about using a pressure washer to accomplish this task. Has anyone ever tried this before and if so did it work? I usually use a long drill bit for my smaller sidewalks (30"). Thanks,
Directional Boring | Information by Electrical Professionals for ...
2011年2月10日 · Directional Boring. Thread starter Mike01; Start date Feb 10, 2011; Status Not open for further replies ...
Advice for a typical 400 amp residential service
2005年9月28日 · Re: Advice for a typical 400 amp residential service Hello suemarkp, thanks for your input. I can see some areas of my configuration wouldn't be feasible with the options I could take within the meter pan, meaning I could hit my ground rod right from the meter and I think I've read somewhere that some meter pans come with the mains in it.
CT orientation question | Information by Electrical Professionals for ...
2022年8月10日 · The voltage doesn't go infinite, just very high. A 400:5 CT is a transformer with 1 primary turn and 80 secondary turns.
How many wire per hole through studs | Information by Electrical ...
2020年1月2日 · The problem is running NM where it's touching and there is no cooling air space. I believe (and I have no code reference for you) that as long as there is at least a 1/8" air gap between cables, you can run as many as you want through the same hole.
Glue that will bond HDPE to PVC Fittings
2024年8月5日 · The product is specifically for electrical conduit and is listed. It is about 60% of the cost of an e-loc coupling (my calculation of labor and material). I turned my directional boring subcontractor on to the product years ago and it is all they use now.
Wires stapled to bottom of joist | Information by Electrical ...
2024年3月5日 · Rationale for restricting perpendicular underside cable attachment is from what I see in 90% of homes that have an accessible basement level is people will use the cable as a hanger rod to hang cloths or other stuff from on the crossing cable.
- 某些结果已被删除