
Choosing Pipe for Main Water Line - GreenBuildingAdvisor
2017年8月10日 · My driveway is 550' long, and the water meter is at the road. So far I have determined I should be happy with a 1.5" ID pipe, for the flow I am considering. I was all set to pull the trigger on HDPE pipe (NSF rated, 200 PSI), until I read some articles that claim this type of pipe becomes brittle with time when exposed to water disinfectants (read chlorine, chloramine, …
Best water line for burying? - Homesteading Forum
2010年2月22日 · PVC if glued right the joints are stronger than the pipe itself. This is the best way, Clean both fitting and pipe with primmer. Then add glue to cover every place the pipe and fitting will have contact meaning the while socket and enough pipe. Push the pipe in and twist it 1/4 turn all in one movement.
Best Underground Plastic Water Pipe/Tube to use?
2012年6月13日 · Re: Best Underground Plastic Water Pipe/Tube to use? 06/14/2012 9:24 AM KJK. you may be better served with a larger line because with a smaller pipe diameter you will experience greater pressure loss due to wall friction.
What size of pipe for a water line from well to house?
2014年11月30日 · Schedule 40 PVC, 1 1/2" to first outside hydrant I like 1" hydrant. Then 1" to house. 3/4" into house to water heater, rest of pipe inside house, 1/2". We always used schedule 80 fitting start and end, slip (glue) to FIP (female iron pipe) thread. Don't use Galvanized pipe anymore especially if you have high minerals.
Sizing Pipe From Well to House - GreenBuildingAdvisor
2020年8月26日 · I am NOT a fan of buried rigid PVC pipe for water well supply line as it can crack and leak in underground applications. I ran 1.25 flexible poly pipe inside a 3" PVC conduit pipe to protect it and it gives it some R-Value protection since it's thermally disconnected from the surrounding soil. Went 24" deep but that depends on where you live.
underground water shutoff? - GreenBuildingAdvisor
2024年4月18日 · Option 3 is to tap into a 3/4″ underground poly pipe that leads to a garden spigot. This cuts the trench length in half, and saves having to hire a contractor to do the well pump install. The complication with this is that the garden spigot has to be shut off seasonally. This is currently done by means of a valve inside the house.
How do you mark underground lines? - Homesteading Forum
2013年6月26日 · However not all lines were marked & some places we had sucker rod, dug down & no water lines. With the new build we have lines underground all around the house it seems. (honestly not happy about it, but to late now). We have 5 wells for the geothermal, septic, electric (buried), propane, dish & water lines.
Best Frost-Free Hydrant Installation Techniques?
2010年11月13日 · When you turn the faucet off, it drains the water down to the bottom of the pipe. You need the water to run away, you need a pile of gravel at the bottom, in my clay soil I ran a 3 inch drain tile along with the water line so the drain water has someplace to go, away from the faucet pipe.--->Paul
how to insulate underground pex | Homesteading Forum
2007年11月9日 · whatever you do, make sure the pipe is free of ground water ever getting to the pex. I wrapped each of my lines with armorflex then wrapped it all with the silver bubble wrap then I wrapped the entire kit and kaboodle with shrink wrap then shoved it all into a 5 inch diameter plastic corrugated field tile.
Foundation Drains - GreenBuildingAdvisor
A. The water enters the perforated pipe through the perforations (holes). Once there is 1/4 inch of water in the bottom of the perforated pipe, the water begins flowing downhill (by gravity) through the solid pipe to the sewer. (By the way, I hope that your municipality allows you do connect a footing drain to the municipal sewer system.