Romex in conduit - Electrician Talk
2017年9月4日 · Can one Romex (14/2 or 12/2) be installed in conduit (1/2" EMT) as a means of mechanical protection sleeve when it's run vertically on an exposed basement wall (concrete) in an unfinished basement with no studs, from the ceiling to plug height (12 inches)? Into an 1110 box, for a single plug. in Ontario Canada, as per Ontario and Canadian code
10-2, 12-2, 14-2 etc? - Electrician Talk
2013年5月14日 · 12/2 for instance means 2 conductors of 12 gauge wire. Typically if you talking about romex, that means black/white and a ground. If you are talking about bx - it just means a black and a white ( the cable jacket is the ground ) but 12/2 MC is typically black/white/green. 12/2 SO cord would be black/white but 12/2 speaker wire would be two 12 ...
Cheat sheet for bored holes - Electrician Talk
2018年1月22日 · Anyone know where I can look up and find a cheat sheet on how many NM cables you can run through various size bored holes when running romex. Mainly referring to 12/2. All replies appreciated .
Romex staples - Electrician Talk
2011年4月11日 · Finally, Viking is introducing a line of plastic “stacking staples” this fall. These will be designed to hold 1-2 or 3 cables and will be color coded for 10, 12 and 14 cable. They will be more expensive than steel staples but they should address this issue in problem areas.
Red 12-2 wire - Electrician Talk
2013年9月5日 · I've wired 2 20A receptacles in my kitchen with red heater 12-2 wire. It was an end of spool sale so I got a good price on it and I needed 12-2 wire so that's why I got it. I knew there were 2 different colors of 12-2 that being red and yellow but the specifications are identical, other than, now that I know after the wiring, the red 12-2 has a ...
Four conductors, two neutrals. | Electrician Talk
2008年2月22日 · I love the Romex 12/2/2 Its perfect for the kithcen's 2 required GFCI protected small appliance circuits. Since people plugs in motor loads such as blenders and such, you can not use a 12/3 multiwire circuit with only one neutral since the GFCI's would nuisance trip over fluctuations on the neutral vs the 2 phases. 12/2/2 let you use only one romex cable to solve …
Where can I find WHITE Romex 12/2 w/g? - Electrician Talk
2009年10月3日 · I am looking for a roll (250 feet) of WHITE Romex 12/2 with ground electrical cable to finish a renovation project I started in my own home years ago before manufacturers started producing color-coded Romex wire. Now I can only find 12/2 with ground in bright yellow, and I want to finish my...
12/2 romex with ground in 2" romex clamp | Electrician Talk
2021年4月9日 · 12/2 romex with ground in 2" romex clamp Jump to Latest 3.2K views 14 replies 10 participants last post by kb1jb1 Apr 10, 2021
30A breaker on a #12AWG wire - Electrician Talk
2014年7月8日 · I have a situation where the loading on a #12 AWG underground service, 12-2/G romex cable in PVC conduit, has increased to 19 amperes. I have had to increase the breaker size to 30 amperes. It will be very difficult, if not impossible, to pull out the #12-2/G and replace with #10AWG wire/cable in the PVC conduit due to the number of turns in ...
12.2 romex white jacket? - Electrician Talk
2012年9月2日 · 12.2 romex white jacket? Jump to Latest 19K views 42 replies 22 participants last post by Briancraig81 Sep 4, 2012