TXV Valve - Indoor and Outdoor? - HVAC-Talk
2008年10月18日 · Welcome to HVAC-Talk.com, a non-DIY site and the ultimate Source for HVAC Information & Knowledge Sharing for the industry professional! Here you can join over 150,000 HVAC Professionals & enthusiasts from around the world discussing all things related to HVAC/R.
Do I really need a TXV valve? - HVAC-Talk
2016年8月8日 · I am replacing my 16 year old central A/C unit (R22) with a new Goodman GSX13 2-ton unit (R410a). I've had several bids and the installer I'd really like to go with recommended I also install a TXV valve instead of a fixed piston. After reading about several problems with TXV valves on this forum, I'm wondering if they're worth the efficiency ...
Bad TXV symptoms - HVAC-Talk
2018年7月18日 · You have a package unit, but bad txv on indoor coil will stop liquid flow. Suction pressure drops, head pressure drops because liquid backs up in condenser. Fan running drops liquid condenser temp and pressure Remove and heat the txv bulb while watching pressures. Valve should open, cool buld, valve should close. Sent from my iPhone using Tapatalk
Bad TXV Valve Diagnosis with additional proposed Leak Test
2020年6月10日 · After failing to get to temp for weeks, tech (35 years in business) states is a TXV valve after monitoring feedback on his system and while adding refrigerant. States hard for most new techs to diagnose properly. States valve probably not fully stuck in our case, but definitely is faulty. Suggests we get a leak test prior to valve replacement.
TXV valve starts banging before furnace comes on- why - HVAC-Talk
2024年4月23日 · The TXV valve bangs and then clicks for a while and then once it stops the furnace turns on appropriately as the thermostat is calling for heat. The outside a/c unit has a cover on in the winter. The banging of the TXV valve only occurs during the winter and when the temperature is above 30 degrees.
Malfunctioning thermostatic expansion valve (TXV) in new
2016年6月1日 · Last fall a professional HVAC contractor installed a new Carrier 4 ton condenser and 4 ton evaporator coil. I ran it for the first time this spring and the coils froze. The HVAC contractor diagnosed a malfunctioning (sticking) thermostatic expansion valve (TXV) and plans to inject a special lubricant into the system to fix the problem.
S-shaped pipe line as bypass to TXV valve - HVAC-Talk
2024年12月14日 · So I replaced it , charged with freon 22, and i saw very high HP and very low LP . I mean HP was going up to 400 psi and LP was 10-15 psi. After minute or two I saw that TXV started freezing and ANOTHER part close to TXV. It is S-shaped pipe line, bypassed TXV, little bit thicker on the middle section of S .
TXV question from a student. - HVAC-Talk
2025年2月18日 · The heat pump TXV does exactly the same thing as the cooling TXV did - after the condensing coil becomes the evaporating coil. The easiest way to draw this is as a close-coupled system using a single by-flow TXV in the liquid line between the condenser coil and the evaporator coil. How are my hints working for you? <g PHM-----
Temperature difference above and below TXV valve - HVAC-Talk
2022年9月21日 · After further diagnosis though, he thought we had a "TXV valve liquid line restriction". He showed me with equipment that it was 75-76 degrees below the TXV valve and 47-46 degrees above it. He said the normal temperature difference should be 8-12 degrees. They recommend replacing the TXV valve. Does this diagnosis and fix sound reasonable to ...
Sporlan TXV valve Installation - HVAC-Talk
2006年7月16日 · My Sporlan TXV valve was installed in 1987 in my 3-4 ton Lennox Central Air Conditioner. The valve top is red-ornage colored and has the number "88" on its top. The bottom where the valve is usually adjusted is attached to the evaporator coil intake.