
WF beam torsion - Structural engineering general discussion - Eng …
2024年11月3日 · I’m using a W21x44 in the first one and framing the exterior wood trusses into the side. For the 2nd detail, I’m using a W12x26 with a WT12x31 because the beam extends past the step so the beam needs to be lower, but the WT is needed for a portion of the span just to pick up the interior wood trusses on the right side of the detail.
Historical shapes - Structural engineering general discussion - Eng …
2010年3月2日 · W21x44 is a very light shape. Upvote 0 Downvote. Mar 2, 2010 #6 paddingtongreen Structural. Sep 28, 2009 ...
W21x44 Dimensions and Structural Engineering Q&A - JustAnswer
For your approximate 40' span and 17' tributary width that supports your ceiling and a flat roof, you can use a W21x44 (50 ksi) steel beam. This beam is 6.5" wide, 20.625"deep and weighs 44 pounds per foot of beam. You will need to provide a timber nailer (2x8) bolted to the top flange of the steel beam.
50ksi W21x44 over 60' long Welding 2 together? 4 - Eng-Tips
2006年6月28日 · 50ksi W21x44 over 60' long Welding 2 together? 4. Thread starter crozroz0000; Start date Sep 7, 2006; Status
Beam-Column Design - Structural engineering general discussion
2001年7月25日 · I have a beam that is supporting two bar joists. There is NO kicker from the bar joist bracing the bottom flange against twist, however, it appears that they considered the bar joist as bracing in the weak direction. Is this standard? The axial load on the original design drawing is 147k. The beam used is a W21x44. Its span is 20'. Fy=36ksi.
Simply Supported Beam Design - Structural engineering ... - Eng …
2004年2月2日 · I am reviewing a design that has a beam subjected to 200k-ft max moment and a 32 ft span, the designer has specified a W21x44. When I checked the beam via ASD the compressive flange would have to be braced at least every 4.7-ft to meet the flange criteria. I think the designer is just...
Expert Answers on Roof Trusses, W21x44 Beams, and 144 x 80 …
Need to size a header for a agricultural building, building is 80x144x18, wanting to install 2- 30’x16’ overhead door on
Steel Beam Bearing on CMU Repair - Eng-Tips
2015年7月6日 · While the beam reaction is low, the beam is likely a long member governed by deflection (hence W21x44). That may mean significant slope at the support and possibly a prying mechanism at the connection plate that somehow dumped a ton of compression right into the CMU head shell and caused it to fracture.
Dining Area Vibration Values - Structural engineering general ...
2005年6月27日 · I go from W21x44 girders with W16x26 nrsmd to W24x55/W21x44's. Upvote 0 Downvote. Mar 10, 2011 #3 rob768
US shapes versus British Shapes - Structural engineering ... - Eng …
2006年4月8日 · I have not found the British Sections limiting in their options - unless I am missing something the difference in wt between W21x44(at 65.4 kg/m) and UB533x165x66 kg/m and W24x55 ( 81.8 KG/m) and UB 610x178x82 kg/m is insignificant.